4. Operation
4.1 Controlling the water flow
The regulating screw on the pipe valve does not have stop protection. Do not unscrew the regulating
screw all the way.
Adjust the water flow rate using a hexagonal Allen key or a Euro cent coin on the pipe valve's
regulating screw:
-
Groove horizontal = max. water flow
-
Groove vertical = min. water flow
4. Maintenance and repairs
• Check the status of the drinking system at regular intervals. Damaged device or heating cables
must not be used or operated further.
• Disconnect the drinking system from the electricity supply during periods when frost is unlikely (e.g. in summer).
• Keep drinking bowl and heating cable free of dust and contamination.
• Clean the drinking bowl and cables using only a soft cloth or damp towel. The cloth or towel must be
free of petrol and/or other solvents, since these can attack or damage the plastic.
5. Spare parts
2220404
2220405
2220151
222015
222018
221886
Regulating screw
This regulating screw also serves as additional frost protection, in
order to restrict damage to the installation, and it will break free
if the drinking bowl freezes up. Before recommissioning, the
broken regulating screw must be replaced by a new screw
(KERBL item number 222018).