INSTRUCTIONS FOR USE
Once work on the vacuum has terminated and before
closing cover "4", check that the filter bags "8" and bearing
cage "9" are vertical.
When the Lever "7" fixed to the operating shaft "2" is in the
neutral central position halfway along its travel, connect
rod "5" to the gearbox "6".
Only in this way will cage "9" cover an equal travel to the
right and left when the gearbox unit is operated.
Shake filter "8" and cage "9" by hand in order to eliminate
any small positioning defects, then tighten the clamp in
filter "8" to fix it in position.
The filter could be torn and the motor of the gearbox burnt
out if this is not done.
Fix the clamp "3" back in place and refit the suction pipe.
The same lever positioning precautions must also be
taken when only the cover is moved and not the filter ring.
EXPLOSION-PROOF VERSION
ATEX
If the vacuum cleaner is used in locations where
combustible and explosive substances are present
Nilfisk-Advance can equip the machine for use in the
categories:
– ATEX Zone 21 (Not previously available);
– ATEX Zone 22, Class "L".
Please contact Nilfisk-Advance if you wish to make use of
these options and require further information.
ATTENTION!
Before commissioning the machine you
should always check that the details given
on the data plate on the machine meet the
safety regulations applicable to the
conditions under which the vacuum cleaner
is to be used.
Make sure that the vacuum cleaner is
suitable for operation in the classification
applicable to the surroundings.
If you have any questions or doubts, contact
your authorised Nilfisk-Advance customer
service centre before operating the
machine.
8
VACUUM CLEANER USED FOR
ABSESTOS
On vacuum cleaners with an accessory for the removal of
asbestos dust the ABS container insert or the protective
bag system must always be used. An exhaust connection
must be attached to the side outlet, through which air can
be exhausted from the working area. The exhaust hose
can be directed to the open air or to a ventilation system
installed in the working area.
The exhaust connection for the air outlet must be fitted
with a 70 mm PUR H hose with a length of < 5 m. This
hose is contained in the Asbestos Kit, which can be
supplied for the machine. As already mentioned, the hose
can either be exhausted directly to the open air or to a
ventilation system installed in the working area.
NOTE
If the machine is to be used for the suction
removal of asbestos dust, either the ABS
container or the protective bag system must
be used.
When transporting the machine you must make sure that
it has been cleaned in accordance with the regulations
stipulated in TRGS 519. The machine can also be
transported in a sealed container from which no
contaminated dust can escape.
Filter replacement
Make sure that the filter is covered with a suitable plastic
bag before it is removed.
Remove the suction pipe "1" from the lower connection.
If the filter assembly is very heavy, remove the upper
cover and lift the assembly from the machine using the two
handles provided. Unscrew the clamp, which attaches the
filter to the basket, and lift the basket from the filter.
Rotate the filter and reveal the plastic strip "2".
Place the filter in a plastic bag, cut the plastic strip and free
the basket from the filter.
Seal the plastic bag containing the filter.