C4
ADAPTING BLOWER FOR OUTSIDE
BACK EXHAUST (cont.)
The fan needs to be rotated counter clockwise
5
180 degrees and rolled 90° to the right to be in
the correct orientation, keeping the blower part of
the fan where the air comes out at the top of the
fan . The wire needs to be reinserted into the case
housing once it has been oriented correctly .
Before Rotation
Back of
Microwave Oven
Before Rolling
Replace screw on the back of the unit .
6
Slide the vent damper on the back of the unit with
7
the hinge at the top .
Slide
exhaust
adaptor into
guides on
microwave
oven rear .
Slide the Blower cover onto the top of the blower
8
plate opening .
Blower Cover
Screw
1" = 2.5 cm; 1' = 0.3 m
50
Installation Instructions
After Rotation
Back of
Microwave Oven
After Rolling
Screw
Damper
(hinge side up)
Exhaust
Adaptor
Back of
Locking
Microwave
Tabs
Oven
Blower Cover
Blower Plate
C4
ADAPTING BLOWER FOR OUTSIDE
BACK EXHAUST (cont.)
Slide the blower plate back onto the microwave
9
by placing the side tabs into the slots and pushing
gently until the back tab is seated into the rear slot,
replace the 3 blower plate screws . Replace the
blower motor screw .
Motor Blower Screw
Blower Cover
29-6379