2.4 Residual risks
Even if you operate this machine according to the instructions, there are always residual risks. The following hazards may occur in connection with the design
and construction of this machine:
a) Lung damage if suitable respiratory protection is not worn.
b) Hearing damage if suitable ear protection is not worn.
c) Damage to health resulting from vibration emissions if the device is used for a long period of time or is not properly managed and maintained.
WARNING!
This machine generates an electromagnetic field during operation. This field may affect active or passive medical implants under certain circumstances. To
reduce the risk of serious or fatal injury, we recommend that persons with medical implants consult their physician and the medical implant manufacturer
before operating the machine.
3. Compressor operation
3.1 Before first use
Remove all packing material and transport locks from the device. Check that
the package contents are complete and undamaged. If possible, keep the
packaging until the warranty period has expired.
3.1.1 Mounting the feet
12
8
13
3.1.2 Mounting the wheels
12
10
Insert the wheel bolt
through the hole in the wheel
11
Pass the wheel bolt
through the hole on the wheel linkage.
11
Fasten the wheel
with the nut
10
Repeat these steps to mount the second wheel
An open-ended spanner (14 mm) is not included in the scope of delivery.
3.1.3 Setting up the device
For safe and correct operation of the device, the installation site must meet the
following requirements:
The floor must be firm, flat and level. Do not place the device in a hot, wet
or very humid environment or near combustible material.
10
GB/IE/NI/CY/MT
Mount the stand 8 with the hexagon
head screw
, as well as the nut
13
shown in the illustration.
An open-ended spanner (12 mm / 13 mm)
is not included in the scope of delivery.
11
.
10
.
12
.
10
The socket must be easily accessible so that the mains plug can be easily
disconnected if necessary. The use of a cable extension is not recommend-
ed. Long supply cables can cause a voltage drop and thus prevent the
motor from starting.
If you still have to use a cable extension, make sure that it is not longer than
5 m and that the cross-section is at least 1.5 mm². ALWAYS use the cable
extension rolled out!
3.2 First use
READ THE MANUAL OF THE PNEUMATIC TOOL BEFORE CONNECTING
as
IT TO THE COMPRESSOR!
12
Make sure that the on/off switch 1 is pressed down. Now
connect the compressor to an earthed socket protected by a
residual current circuit breaker.
3.2.1 Switch on/off
Pull the on/off switch 1 upwards. The compressor is switched on.
To switch off the compressor, press the on/off switch 1 down.
3.2.2 Air pressure presets
The following pressures are preset:
- Switch-on pressure: approx. 6 bar
- Cut-off pressure: approx. 8 bar
3.2.3 Setting the air pressure
With the pressure regulator 3 you can set the desired pressure (0 -8 bar).
Pay attention to the nameplate of the pneumatic tool to be connected!