mundoclima Aerotherm BCC 200 CONNECT Manuel D'installation, D'utilisation Et D'entretien page 159

Masquer les pouces Voir aussi pour Aerotherm BCC 200 CONNECT:

Publicité

Size
Ventilation
Type of fan
Air flow
Available pressure head
Integration
Solar coil surface
Solar coil material
Maximum operating pressure
1. Inlet water temperature 15 °C, accumulator set 45°C, air on source side 15°C D.B /12°C W.B.
2. The product complies with the European Directive ErP, which includes the Commission Delegated Regulation (EU) N. 812/2013 and the Commission Delegated Regulation N.
814/2013, Average Climate, Heat Pump Water Heater
3. The product complies with the European Directive ErP, which includes the Commission Delegated Regulation (EU) N. 812/2013 and the Commission Delegated Regulation N.
814/2013, Warmer Climate, Heat Pump Water Heater
4. The product complies with the European Directive ErP, which includes the Commission Delegated Regulation (EU) N. 812/2013 and the Commission Delegated Regulation N.
814/2013, Colder Climate, Heat Pump Water Heater
5. Data referred to completely ducted unit.
6. Maximum temperature that can be reached during Anti-legionella mode(Dinsifect)
*It contains fluorinated greenhouse gases
Electrical data
Size
Power supply
F.L.A. - Current absorbed at the maximum allowed conditions
F.L.I. - Power absorbed at full load (at the maximum allowed condi-
tions)
M.I.C - Maximum inrush current
1) Power supply 220-240/1/50 Hz
For power voltages other than the standard, contact the technical department
The units are conforming with the prescriptions of European Standards CEI EN 60204 and CEI EN 60335
Warning: when defining the correct size, verify that all absorption is compliant with current electrical supply
contracts in force in the country of installation
Operating limits
200 - 200S
1. Use range of the heat pump
2. Use range of the electrical heating element
3. Use range of the electrical heating element only in Anti-Legionella mode
(Disinfect)
13 TECHNICAL DATA
3
m
/h
Pa
2
m
bar
MPa
200
(1)
220-240/1/50
V
A
9,10
kW
2,10
A
22,2
70
60
50
40
30
20
10
0
-25
Twu [°C] water temperature in the accumulator
Tae [°C] air temperature at exchanger inlet
200
300
Centrifugal
270
414
25
45
-
-
-
-
-
-
-
-
300
200S
220-240/1/50
220-240/1/50
9,80
9,10
2,25
2,10
33,7
22,2
300 - 300S
3
2
-20
-15
-10
-5
0
5
10
15
Tae [°C]
200S
300S
270
414
25
45
1,10
1,30
Enamel Steel
10
10
1
1
300S
220-240/1/50
9,80
2,25
33,7
2
1
20
25
30
35
40
45

Publicité

loading