Kickback Control:
The electronics in the power tool detects situ-
ations where the wheel or accessory may be at
risk to bind . The electronics prevents further
rotation of the drive spindle by switching the
power tool off (it does not prevent kickback) .
To resume operation, turn on/off switch to the
off position, then restart tool .
Constant Response Circuitry:
Helps maintain near constant RPMs between
no-load and load conditions .
Soft Start:
Helps reduce stress on the motor that occurs
from a high torque start . Helps bring accessory
smoothly up to speed .
14
GWS11-450P_Final_20240417.indd 14
GWS11-450P_Final_20240417.indd 14
Functional Descriptions
page heading
Automatic Restart Protection:
Helps prevent accidental startups after power
has been interrupted, e .g . the tool was un-
plugged with the switch locked in the on posi-
tion . To resume operation, turn on/off switch to
the off position, then restart the tool .
Overload Protection:
Helps protect tool from excessive heat that may
damage motor . If tool stops or slows during
operation, allow motor to cool for 30 seconds
by running no-load . If the overload protection
stops the tool repeatedly, excessive force is
causing the tool to overload . Stop excessive
force and readjust work piece to reduce force
applied .
4/17/2024 10:53:13 AM