Télécharger Imprimer la page

ATH-Heinl ATH Frame Lift 30FZ Mode D'emploi page 88

Publicité

4.2
Emergency lowering in the event of a power failure
2
1
1. Switch off the lift using the main switch and secure it against being switched on again
2. Open the front cover of the control box
3.
Actuate the control valves
4.
The lowering movement of the lift is triggered by turning the screw on the lowering valve anticlockwise.
is triggered.
Attention
Do not overtighten the screw.
The lowering speed during emergency lowering may otherwise be too high.
5. After the lift has been lowered completely, all screws must be tightened again.
4.3
Consumables for assembly, maintenance and care
Hydraulic oil
Minimum requirement
Eni PRECIS HVLP-D Item no.: 090536 (10 liters) 90537 (10 liters)
® Copyright ATH-Heinl GmbH & Co. KG / All rights reserved / Misprints and technical changes reserved