When installing on storey ceilings, their sufficient load-bearing capacity must be checked. It is generally
recommended that a building expert be consulted for an expert opinion when installing on storey ceilings.
2.6
Electrical connection
Attention
The general and local regulations must be observed. Therefore, this step may only be carried
out by a trained specialist.
Pay attention to the necessary supply line.
The connection should be made according to the product with a CEE plug, 5-pin, 400V/16A.
Voltage deviations should not exceed 0.9 - 1.1 times the nominal voltage range and frequency deviations should
not exceed 0.99 - 1.01 times the frequency range. To be able to guarantee this, necessary protective measures
must be taken.
At the end of the work, the direction of rotation of the motor must be checked.
2.7
Pneumatic connection
Attention
For all pneumatic systems, a compressed air maintenance unit (sometimes included in the
scope of delivery) must be fitted between the supply line and the system.
The air pressure of the supply line must at least correspond to the
The correct setting of the compressed air maintenance unit must be checked.
The compressed air maintenance unit must be serviced at regular intervals.
The maximum or minimum pressure ensures proper function without possible damage.
2.8
Hydraulic connection
Before the system is put into operation or operated with oil for the first time, the following must be
observed with regard to optimum, trouble-free and virtually air-free operation:
All hydraulic lines must be connected and tightened in accordance with the hydraulic diagram and, if
applicable, the hose designation.
All hydraulic lines and cylinders must be vented according to the hydraulic plan or hose designation.
In order to ensure the proper and safe functioning of the system and the hose lines used, it is essential to
ensure that the hydraulic fluids used comply with the specific specifications and recommendations of the
manufacturer.
Media used that do not meet the specific requirements or are contaminated will damage the entire hydraulic
system, shorten the service life of the hydraulic systems used and lead to the exclusion of liability and
warranty.
® Copyright ATH-Heinl GmbH & Co. KG / All rights reserved / Misprints and technical changes reserved
74
Release date: 27.09.2024 / Product manufacturer ATH-Heinl GmbH & Co. KG
"Technical
data".