1. After the first filling with hydraulic oil, the Lift button must be pressed for approx. 30 seconds to pump the oil
into the hydraulic circuit.
2. Raise the lifting platform to the maximum lifting height (must not exceed 1900 mm).
3.
Open the top cover of the switch box and press the button to bypass the limit switch
by pressing the Raise button
light barrier
if necessary) and the transparent return hose is completely filled with oil.
4. Lower the lifting platform completely by pressing the Lower button. Do not release the Lower button yet.
5. Keep the Lower button pressed for another 10 seconds to allow any residual air to escape.
6. Repeat the lifting and lowering process at least two more times.