Setting the CE-Stop switch
1. Position the lifting platform at a height of 300 mm.
2.
Loosen the screw of the adjustment wheel on the inside of the main scissors
3. Turn the wheel until the limit switch is active (red LED lights up).
4. Tighten the screw on the adjustment wheel again.
The CE-Stop height is set.
ü
2.10
Before commissioning
Warning
Before commissioning, check all fastening screws, electrical, pneumatic and hydraulic lines
and tighten them if necessary.
Caution: Some of these must be checked at regular intervals and retightened if necessary.