13.2.1
Maintenance plan
The type and degree of machine wear depend to a large extent on the operating conditions. The
intervals given below apply when the machine is used within the technical limits:
Interval
Before starting work
Monthly
After 100 operating
hours or each year
13.2.2
Charging batteries
 Before charging, check the charger (cable, plug, housing) for damage or defects. Never use a
defective charger.
 Only use chargers recommended by the manufacturer to charge the battery. Never use chargers
that are not intended for the battery type (fire hazard!).
 Switch off the charger or disconnect the voltage supply to the charger before connecting or
disconnecting the battery.
 Charge the battery in an upright position.
 Avoid overheating when charging the battery. Ensure sufficient air supply so that no heat build-
up can occur.
 Allow the battery to cool down after heavy use before charging.
 Always charge the battery in a well-ventilated area.
 Do not smoke when charging the battery. Keep the battery away from open flames and sparks.
Oxyhydrogen gas, which is produced when charging the battery, is explosive.
 Allow battery to cool immediately after charging.
 New batteries should be charged for at least 12 hours before use.
 Do not overcharge batteries, the max. charging time of 30 h should not be exceeded.
13.2.3
Replace hydraulic oil
ZIPPER MASCHINEN GmbH
www.Zipper-Maschinen.at
Components
Screws connection, hub
nuts
Cable connections
Brake system
Batteries
Batteries
wheel axle and tilting shaft
tray
Hydraulic oil is toxic and must not be released into the environment! Follow
the instructions of the supplier and, if necessary, contact your local
authorities for information on proper disposal.
CLEANING, MAINTENANCE, STORAGE, DISPOSAL
Check for tight fit, tighten if necessary.
Check for tight connection.
Check for function.
Check for cleanliness and dryness.
Check battery status, recharge if
necessary.
Charge batteries
Lubricate
Position the machine on a level surface.
Connect the charger to the charging socket of the
machine (1) and to the power supply. The battery is
charged, duration approx. 6-7 h.
Read the charging status on the control panel.
After complete charging, disconnect the charger
from the machine and from the charging socket.