7.1.3 Configuring the product
Defining units
Units
Temperature
Pressure
Abs.
Humidity
back
Fig. 7: Submenu Sensor Setup: Units
1. Select the unit for temperature.
2. Select the unit for pressure.
3. Select the unit for absolute humidity.
Calculating the dew point at atmospheric pressure or reduced
pressure
Pressure
Ref.
Pressure
Sys.
Pressure
back
Fig. 8: Submenu Sensor Setup: Pressure
1. Enter the atmospheric pressure or reduced pressure as the reference pres-
sure.
2. Select the unit for the reference pressure.
3. Enter the system pressure.
4. Select the unit for the system pressure.
ð The dew point at atmospheric or reduced pressure is displayed on the 3rd
page in the main menu.
AVENTICS™ DS1 | R412029167-BAL-001-AA | English
°F
°C
back
psi
bar
mbar
hpa
Mpa
back
mg/m³
g/m³
back
0...99999,9
psi
Unit
bar
mbar
hpa
Mpa
OK
CLR
Cancel
OK
Cancel
0...99999,9
psi
Unit
bar
mbar
hpa
Mpa
OK
CLR
Cancel
OK
Cancel
Calibrating the product
Calibration
Reference
Value
Calibrate
Reset
back
back
Fig. 9: Submenu Sensor Setup: Calibration
1. Enter the reference value.
2. Select the Calibrate button.
Resetting the calibration
Select the Reset button.
u
7.1.4 Configuring Modbus RTU
1...247
ID
back
1
Stop
2
back
on
Term.
off
back
1200
Baudrate
2400
4800
9600
19200
38400
back
Fig. 10: Submenu Modbus Setup: Modbus ID
none
Parity
even
odd
back
0-??ms
RespDelay
back
ABCD
Format
CDBA
back
Set to
Default
back
Fig. 11: Submenu Modbus Setup: Parity
1. Set the Modbus ID, Baud rate, Parity and Stopbit parameters. See
g 11.2.1 Modbus
parameters.
+/-
0...99
CLR
OK
Cancel
20