Procedure
1. Use a quick-disconnect coupling to connect the sensor to the compressed air
line.
2. For compressed air containing oil or dirt: Install a prefilter upstream of the
measuring chamber.
6.4 Connecting the electrical system
1. Optional: Connect M12, 5-pin, A-coded plug connector.
2. Optional: Connect M12, 8-pin, X-coded plug connector.
3. Close off all unused ports.
7 Commissioning
7.1 Step-by-step commissioning
• Step 1:
g 7.1.1 Switching on the product
• Step 2:
g 7.1.2 Calling up the settings menu
• Step 3:
g 7.1.3 Configuring the product
• Step 4a:
g 7.1.4 Configuring Modbus RTU
• Step 4b:
g 7.1.5 Configuring Modbus TCP
• Step 5:
g 7.1.6 Changing the user preferences
• Step 6:
g 7.1.7 Configuring the channels
7.1.1 Switching on the product
Switch on supply voltage.
u
ð The main menu appears in the display.
English is used as the display language in the illustrations and instructions below.
To change the display language: See
AVENTICS™ DS1 | R412029167-BAL-001-AA | English
g 7.1.6 Changing the user
preferences.
7.1.2 Calling up the settings menu
Main
Main
menu 1
menu 2
Enter Password
<
1
2
3
4
5
6
7
8
9
0
Settings
OK
menu
CANCEL
Sensor Setup
ModBus Setup
Alarm Setup
User Setup
Advanced
4 - 20mA
Network Setup
Info
Back to Main
Fig. 6: Main menu and settings menu
1 Sensor Setup
See
g 7.1.3 Configuring the
product.
3 User Setup
See
g 7.1.6 Changing the user prefer-
ences.
5 Network Setup
See
g 7.1.5 Configuring Modbus
Enter password. Default: 0000.
u
Main
menu 3
1
2
3
4
5
2 ModBus Setup
See
g 7.1.4 Configuring Modbus
RTU.
4 4 ... 20 mA
See
g 7.1.7 Configuring the chan-
nels.
TCP.