1.
Push the energy converter on the chair with soft materials (such as a towel). Insert the small spanner into
the horn spanner hole and the large spanner into the transducer spanner hole, with the large and small
spanners positioned to the left and right.
2.
Stand facing the horn, holding the large spanner in your left hand and the small spanner in your right.
Firmly tighten by pressing downward with both hands (ensuring it is securely tightened).
3.
When replacing the horn, such as the M10 screw on the horn, remove it by hand. Then, securely fasten
the bolts on the transducer. If a hex wrench cannot loosen the bolts on the horn, lightly tap the bolts on a
wooden surface a few times to allow them to loosen.
EN
F- M10 bolt
G- Small spanner hole
H- Amplitude transformer
I-
Small spanner