7
Storage
Carry out the following work every 6 months:
–
Check that the system is functioning correctly:
–
Switch on the thermal imaging camera and the In-Mask Display and pair
them.
–
Check that a thermal image is displayed in the In-Mask Display.
–
Switch the thermal imaging camera and the In-Mask Display off again.
–
Charge the batteries in the thermal imaging camera and the In-Mask
Display.
–
Replace the battery when its runtime is no longer sufficient.
Dräger recommends keeping the thermal imaging camera and the In-Mask
Display in their charging cradles so that the rechargeable batteries will be
regularly recharged.
8
Disposal
This product must not be disposed of as household waste. This is indi-
cated by the adjacent symbol.
You can return this product to Dräger free of charge. For information
please contact the national marketing organizations or Dräger.
9
Technical data
Weight
Dimensions of the In-Mask Display
(W*H*L)
Charging cradle (W*H*L)
Focal length
Resolution (pixels)
Display window material
Degree of protection
Battery technology
Operating time
Charging time
Ambient temperature for continuous
operation
Ambient temperature during charging
Dräger FPS IMD
Approx. 140 g
Approx. 140 mm x 70 mm x 60 mm
12 mm x 7.5 mm x 18 mm
15 mm
640 x 400
PMMA, coated
IP 67
Lithium ion
1)
typically 10 h
at +20 °C
max. 4 hours
-20 °C to +45 °C
+10 °C to +40 °C
|
Storage
en
29