1 - Poor water drainage. Stagnant water in the slat supports:
- Check that the structure is not on an inverted slope. Remove all the slats from the structure and level the structure.
2 - When water leaks through the feet:
- Poor watertightness of the front casing trim panels. Check or make the watertightness between the front profile trim
panels and the front box.
3 - Water leakage at the louvres:
- The slats do not close properly. Re-prepare the cylinder and set the working time. With the blades closed, loosen the
BSO4204, extend the 4 mm piston, retighten the BSO4204 and repeat the setting of the working time.
4 - The slats do not open:
- Make sure that the pistons are in tension.
- Check the electrical wiring. Be careful to cut off the power in case of tampering.
- Repeat the setting of the working time with all the blades assembled without the second and third blades.
- Check that the structure is square.
- Check the assembly of the control profiles.
5 - The screws of the piston are rubbing against the frame of the structure :
- Check the assembly of the control profiles.
6 - When assembling the frame, the feet of the front profiles are not level (90°):
- Problem of perpendicularity. Level the frame or calibrate the floor mounting brackets.
8 - The LED strip stays on continuously:
- Check that the cable passes through the PBSO47. Check that the LED cable is not stripped and in contact with the
PBSO47. Disconnect the power supply in case of manipulation.
9 - One of the LED strips illuminates less than the others or one LED does not illuminate in the centre of the strip:
- Malfunction in the LED strip. Replace the LED strip.
10 - A day appears between the upper profile and the first slat:
- Normal phenomenon of bending of the first louvre. This phenomenon does not cause leakage.
11 - Condensation under the slats:
- Phenomenon of a large external temperature change. This natural phenomenon does not affect the quality of the bio-
climatic pergola.
*** Translated with www.DeepL.com/Translator (free version) ***
Maintenance tips for the slatted pergola:
A pergola with slats is subject to various restrictions: humidity, salty air, wind...
Our recommendation is:
check
that all bolts and nuts are tightened after installation, do it regularly: at the beginning and at the end of
the season.
clean
the structure at the beginning and end of the season. Attention, do not use detergent products
Do not open the pergola in case of:
Waterproof in case of
rain.
Rainy