Synchronised cylinder programming.
28
Information: various configuration parameters.
Configuration menu
Synchronisedc menu
Independent menu
Not used.
Single menu
Not used.
Other dialogues.
Cylinder in stop
open position
Cylinder in opening
movement
Deletion of remote
control radio code
and climate sensor.
First Ignition.
A
Cylinder configuration. Synchronised 2-cylinder mode.
B
WARNING!
Before performing any other operation, it is necessary to configure the actuator. If the actuator is not configured, it will not be
possible to actuate the actuator or to teach-in the radio transmitter. In this condition, the LEDs relating to Motor 1 and 2 are off.
INSTALLATION TYPE CONFIGURATION = 2 synchronised cylinders.
3 - Using the 'UP' or 'DOWN' buttons, select
'Sincr'.
Page 22
On first start-up, the control unit display will show this condition:
- 2 dashes corresponding to Motor 1 (--),
- 2 dashes corresponding to Motor 2 (--),
This means that the motors have not yet been configured.
WARNING! NO OPERATION WILL BE POSSIBLE!
5s
5s
1 - Hold down 'MENU' for 5s
(until 'MConF' is displayed).
Cylinders in Synchronised mode
Cylinders in Independent mode
Not used.
Single mode cylinders
Not used.
Cylinder in stop/
close position
Cylinder in closing
movement
RESET
AUTOMATIC.
Synchronised mo-
tors (M1 + M2)
2 - Release the 'Menu' button, then hold it down for 5s
(until one of the 3 screens on the right appears).
4 - Press and hold the 'Menu' button for 5
seconds to confirm the mode.
Movement of cylinder 1 (M1) and
cylinder 2 synchronised by remote
control.
5s
5s
15s
15s
5 - Wait 15s, 'Cl oo' appears.
LED MOTOR 1 - 2 is lit.
5s
5s
Remote
control lear-
ning