3.4.4 CAN-Bus
battery chargers have two terminals made for connectors Molex Microfit 3.0, 6 circuits (reference 43045-
0600).
Documentation n° 1336205REG_CAN (hardware and software specification) is available upon request.
Protocol
CAN-Bus protocol can be chosen with the programming field 3 (see 3.3.4).
Power Supply
The power supply of the CAN-Bus can either be carried out by another
equipment or by the charger itself.
To generate the power supply, simply move the two jumpers JP1 and JP2 to
position 1-2.
Communication
To allow communication between multiple devices, each entity must have a
unique identifier (ID). This identifier must be selected using the 4 micro
switches (1,2,3,4).
Switches settings
1
2
3
0
0
0
1
0
0
Factory settings
0
1
0
1
1
0
0
0
1
1
0
1
0
1
1
1
1
1
0
0
0
1
0
0
0
1
0
1
1
0
0
0
1
1
0
1
0
1
1
1
1
1
Device number
4
0
0
0
1
0
2
0
3
0
4
0
5
0
6
0
7
1
8
1
9
1
10
1
11
1
12
1
13
1
14
1
15
Jumpers JP1 et JP2
Dip switches :
(1, 2, 3, 4)
45