Special precautions should be taken on any installation prone to
electrolyze phenomena. Electrical standard requires a battery
switch as close as possible to the batteries.
Precautions regarding lightning
In areas highly exposed to lightning, it may be advisable to install a
lightning arrestor upstream of charger to safeguard it against
irreversible damage.
Precautions regarding overheating of the appliance
This appliance is designed to be mounted on a vertical wall or
partition as indicated herein.
It is imperative that there be a gap of 150mm around the charger.
The installer must ensure that the temperature of the air at the
input is lower than 65°C in extreme operating conditions.
Measures should also be taken to allow evacuation of hot air on
either side of the charger.
It's strictly forbidden to put any device on or against the charger.
The charger must not be installed near a heat source; it should be
installed in a well-ventilated area. The charger's air inlets and
outlets must not be obstructed.
Attention hot surface: do not touch the charger during and
after its operation (burn hazard).
Precautions regarding dust, seepage and falling water
The charger should be located so as to prevent penetration of
damp, liquid, salt and dust, any of which could cause irreparable
31