Télécharger Imprimer la page

FAAC E045 Guide Rapide page 17

Masquer les pouces Voir aussi pour E045:

Publicité

S4
will flash on the display: leaf 1 will begin its closing movement.
7.
Operation WITHOUT Encoder
Stop the movement by sending an OPEN
A pulse as soon as leaf 1 reaches the
mechanical stop.
8. The board will automatically exit the programming menu and will display the status of the auto-
00
mated system (
If the procedure is not completed correctly,
new SET-UP procedure must be performed.
The deceleration spaces can be configured and modified from the
parameters on the display (refer to Advanced Programming) without having to
repeat the SET-UP.
5.
USEFUL PARAMETERS TO PROTECT AGAINST THE RISK OF IMPACT/
CRUSHING ON THE MAIN EDGE
PARAMETER
FUNCTION
Allows the static thrust force of motor 1 to be adjusted.
F1
NOTE: For hydraulic operators, set the force value to maximum and adjust it via
the bypass screws.
Allows the static thrust force of motor 2 to be adjusted.
F2
NOTE: For hydraulic operators, set the force value to maximum and adjust it via
the bypass screws.
En
Enables the encoders to be read by the electronic board, thereby guaranteeing that
inversion occurs in the presence of obstacles (set
Allows the closing delay of motor 1 to be modified in order to obtain a phase shift
Cd
between the two leaves and reducing the risk of crushing between the two moving
leaves.
r1
Allows the space of reduced speed of leaf 1 to be adapted. The impact at slow speed
allows the dynamic force to be reduced.
r2
Allows the space of reduced speed of leaf 2 to be adapted. The impact at slow speed
allows the dynamic force to be reduced.
EC
Allows the obstacle inversion sensitivity to be adjusted.
rB
Allows the space before the mechanical stops in which the board does not
perform inversions to be modified (set a value between 1 and 49 mm).
E045
) as confirmation that the SET-UP procedure has been completed correctly.
Operation WITH Encoder
Leaf 1 will stop as soon as it reaches the
mechanical stop. If there is no mechanical stop,
stop the leaf movement at the desired point by
sending an OPEN A pulse.
S0
will start flashing on the display, indicating that a
EN
9
r1
r2
and
Y
=
).
732785 - Rev.D