These beeps can be suppressed if they seem too noisy to you. To do this, simultaneously
press
as you switch On with the rotary switch. The disappearance of the
MIN MAX
symbol from the screen shows that the beep is switched Off. This deactivation of the
beep will be continued even after the instrument is switched Off (switch to the OFF position).
To activate the beep function again, switch the instrument On again, whilst simultaneously
pressing
.
MIN MAX
DISPLAYING THE PRESENT TIME
A digital clock allows the display of the present time as well as the time of the different
recordings or memorisations.
This clock operates permanently, even when the instrument is asleep or completely switched
Off, which makes it possible to display the precise time as soon as the instrument is switched
On.
This clock displays hours and minutes in accordance with the international 24 hour standard.
When the time is displayed, the ¿ symbol appears opposite the display of a session which
is announced by the Dt symbol being lit.
A colon (:) is displayed between the hours and the minutes, if it flashes this shows that the
time displayed is the present time. When it is continuously displayed, this indicates that the
time displayed is a set time corresponding to the moment when the displayed measurement
was recorded.
To display the present time, simultaneously press
when you switch On with
SMOOTH
the rotary switch. Similarly, to cancel the display of the present time, you must switch Off
your instrument (switch to the OFF position) then simultaneously press
whilst
SMOOTH
turning the switch.
Notes :
When changing the battery, a reserve power supply ensures normal operation of the clock for
one minute.
If the power supply to the clock is cut, the clock displays 0:00 flashing for one minute, then
starts normal operation again from 0:01 (new present time).
PRINTOUT OF THE PROGRAM MEMORY
To print the contents of the program memory, press
simultaneously when
PRINT
switching On with the rotary switch (the PRINT symbol is displayed when pressed).
This command is active when the button is released. At this time, the PRINT symbol
disappears while the COM symbol appears indicating transmission.
53