Automatic Printout; Program Mode - Chauvin Arnoux C.A 43 FILEDMETER Mode D'emploi

Mesureur de champ large bande
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

AUTOMATIC PRINTOUT

When the Scanning function (printout every n minutes) is programmed, press
start the measurements printing cycle with the SCAN time interval programmed.
This cycle starts by printing the measurement displayed when this command is sent.
The SCAN symbol remains lit on the display throughout the duration of operation of the
automatic printout mode. At each printout, the COM symbol lights up during data output.
If the programmed duration exceeds 10 minutes and Auto Off has not been cancelled, the
instrument will go to sleep automatically after the first 10 minutes, then will wake up again at
the time of the new transmission, then will go to sleep again until woken again automatically.
To interrupt the programmed sequence, press
SCAN symbols disappear from the display).
During operation of the automatic printout function, press one of the buttons or turn the rotary
switch to interrupt the current print cycle (the
display).
ALARM / D D D D D t SESSION / CLOCK ¿ / SCAN RATE
Pressing the
PRGM
mode. The PRGM symbol lights up on the display.
This command blocks all the functions which are in service including the digital output. The
different symbols of these functions disappear and the instrument does not make any more
measurements. All the buttons then give access to the second functions printed in yellow on
the case. A second press on
and to validate the programming.

PROGRAM MODE

button on Measurement mode allows you to activate the Programme
PRGM
PRINT
P
and SCAN symbols disappear from the
allows you to return to normal measurement mode
66
a second time (the COM and
to
PRINT

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

1670.02C.a 43

Table des Matières