Display Icons Description & Action (if needed)
Sieve (columns) reset
This symbol is displayed when column maintenance is required and once the replacement col-
umns have been installed.
Sieve reset success
This symbol is displayed once the sieve columns have been successfully reset.
Data log transfer in progress or update in progress (app only)
This icon is displayed during all data log transfers and software updates initiated through the
Inogen Connect app.
Data log transfer success (app only)
This icon is displayed after data log transfers have been successfully completed through the
Inogen Connect app.
The following displayed icons are accompanied by a single, short beep.
Please wait, shutting down
Power button has been pressed for 2 seconds. Concentrator is performing system shut down.
Life Clock (HH:MM), software version & serial number display (Vx.x:SN)
This will show up when the 'No-breath-detect' audible alarm button (bell button) has been
pressed for five seconds while the concentrator is running.
8.5. ALARMS
The device monitors various parameters during operation and utilizes an intelligent alarm system to indicate a mal-
function of the concentrator. Mathematical algorithms and time delays are used to reduce the probability of false
alarms while still ensuring proper notification of an alarm condition. If multiple alarm conditions are detected, the
highest priority alarm will be displayed. Note that failure to respond to the cause of an alarm condition potentially
will result in discomfort or reversible minor injury only (e.g., reduced oxygen supply or a burn). In case of an alarm,
seek to address the issue and/or switch to a backup source of oxygen.
WARNING!
Risk of injury or damage
• Audible alarms are to warn the user of problems. To ensure that audible alarms may be heard, the maxi-
mum distance that the user can move away from it must be determined based on the surrounding noise
level. Make sure the device is in a location where the alarms can be heard or seen if they occur.
The following section provides a listing and description of every possible alarm condition. The alarm system is
intended to notify an operator while wearing the device in a shoulder bag or while the device is set down within
range of an acceptable nasal cannula.
The device performs an alarm system auto-check on startup by illuminating all LED's and briefly activating the audi-
ble alert signal. If the power plug is removed when a battery is connected, the alarms will work normally. If there is
©2022 Inogen, Inc. All rights reserved.
Page 28 of 356
96-12100-01-01-A