Télécharger Imprimer la page

Bosch NIT5060UC Instructions D'installation page 10

Masquer les pouces Voir aussi pour NIT5060UC:

Publicité

en-us Checking the installation
Models
NIT8461UC
NIT8061UC
5.2 Connecting electrical supply
WARNING
Before installing, turn power OFF at the service panel.
Lock service panel to prevent power from being turned
ON accidentally.
Note: If the cooktop is installed and connected as
specified here, it will be grounded in compliance with the
National Electrical Code.
Install a suitable junction box (not furnished).
1.
The branch-circuit breakers ampacity, the wire sizes
and the connections must conform to the requirements
of the National Electrical Code or Canadian Electrical
Code and all local codes and ordinances.
Attach the flexible conduit to the junction box.
2.
10
240 V AC, 3-wire, 60 Hz system: circuit
breaker
30 A
30 A
208 V AC, 3-wire, 60 Hz system: circuit
breaker
30 A
30 A
Connect the lead wires to the junction box supply wires
3.
in proper phase.
1
2
3
Red wires
1
UL listed wire connectors
2
Green (or bare) ground wire (from appliance)
3
Cable from home power supply
4
Black wires
5
Junction box
6
Flexible conduit from appliance
7
– Black wires of cooktop to black house wire
– Red wires of cooktop to red house wire
– Green or bare to ground
6 Checking the installation
Checking the installation
Check if your unit is working properly after you have
Checking the installation
completed the installation steps.
WARNING
Before you turn on power supply, make sure all controls
are in the OFF position.
Remove everything from the cooktop surface including
1.
stickers.
Clean the cooktop surface with cooktop cleaning cream.
2.
Switch on the circuit breaker.
3.
Verify that all cooking zones function properly.
4.
4
5
6
7

Publicité

loading