Télécharger Imprimer la page

Makita DLS211ZU Manuel D'instructions page 35

Scie radiale sans fil

Publicité

Tool registration for the vacuum
cleaner
NOTE: A Makita vacuum cleaner supporting the
wireless activation function is required for the tool
registration.
NOTE: Finish installing the wireless unit to the tool
before starting the tool registration.
NOTE: During the tool registration, do not pull the
switch trigger or turn on the power switch on the
vacuum cleaner.
NOTE: Refer to the instruction manual of the vacuum
cleaner, too.
If you wish to activate the vacuum cleaner along with
WKH VZLWFK RSHUDWLRQ RI WKH WRRO ¿QLVK WKH WRRO UHJLVWUD-
tion beforehand.
1.
Install the batteries to the vacuum cleaner and the
tool.
2.
Set the stand-by switch on the vacuum cleaner to
"AUTO".
Fig.70: 1. Stand-by switch
3.
Press the wireless activation button on the vac-
uum cleaner for 3 seconds until the wireless activation
lamp blinks in green. And then press the wireless acti-
vation button on the tool in the same way.
Fig.71: 1. Wireless activation button 2. Wireless
activation lamp
If the vacuum cleaner and the tool are linked success-
fully, the wireless activation lamps will light up in green
for 2 seconds and start blinking in blue.
NOTE: 7KH ZLUHOHVV DFWLYDWLRQ ODPSV ¿QLVK EOLQNLQJ
in green after 20 seconds elapsed. Press the wireless
activation button on the tool while the wireless acti-
vation lamp on the cleaner is blinking. If the wireless
activation lamp does not blink in green, push the wire-
OHVV DFWLYDWLRQ EXWWRQ EULHÀ\ DQG KROG LW GRZQ DJDLQ
NOTE: When performing two or more tool registra-
WLRQV IRU RQH YDFXXP FOHDQHU ¿QLVK WKH WRRO UHJLVWUD-
tion one by one.
Starting the wireless activation
function
NOTE: Finish the tool registration for the vacuum
cleaner prior to the wireless activation.
NOTE: Refer to the instruction manual of the vacuum
cleaner, too.
After registering a tool to the vacuum cleaner, the
vacuum cleaner will automatically runs along with the
switch operation of the tool.
1.
Install the wireless unit to the tool.
2.
Connect the hose of the vacuum cleaner with the tool.
Fig.72
3.
Set the stand-by switch on the vacuum cleaner to
"AUTO".
Fig.73: 1. Stand-by switch
4.
Push the wireless activation button on the tool
EULHÀ\ 7KH ZLUHOHVV DFWLYDWLRQ ODPS ZLOO EOLQN LQ EOXH
Fig.74: 1. Wireless activation button 2. Wireless
activation lamp
5.
Pull the switch trigger of the tool. Check if the
vacuum cleaner runs while the switch trigger is being
pulled.
To stop the wireless activation of the vacuum cleaner,
push the wireless activation button on the tool.
NOTE: The wireless activation lamp on the tool will
stop blinking in blue when there is no operation for
2 hours. In this case, set the stand-by switch on the
vacuum cleaner to "AUTO" and push the wireless
activation button on the tool again.
NOTE: The vacuum cleaner starts/stops with a delay.
There is a time lag when the vacuum cleaner detects
a switch operation of the tool.
NOTE: The transmission distance of the wireless unit
may vary depending on the location and surrounding
circumstances.
NOTE: When two or more tools are registered to one
vacuum cleaner, the vacuum cleaner may start run-
ning even if you don't pull the switch trigger because
another user is using the wireless activation function.
35 ENGLISH