Pressure testing
The gas pressure can be measured
at the injector of one of the Left Hand
hotplate burners. Remove the pan
support, burner head and cap. The in-
jector is now accessible.
See Technical data section at the
back of this book for test pressures.
Reassemble burner top, making sure
it is reassembled in the correct way
on the burner body.
Electrical Connection
This appliance must be installed by a
qualified electrician to comply with the
relevant regulations and also the local
electricity supply company require-
ments.
WARNING:
THIS
APPLIANCE
MUST BE EARTHED
Note
The cooker must be connected to the
correct electrical supply as stated on
the voltage label on the cooker,
through a suitable cooker control unit
incorporating a double pole switch
having a contact separation of at
least 3mm in all poles. This cooker
must not be connected to an ordinary
domestic power point.
The total electrical load of the appli-
ance is approximately 7.4kW. The ca-
ble size used should be suitable for
this load and comply with all local re-
quirements.
Access to the mains terminal is
gained by removing the electrical ter-
minal cover box on the back panel.
Connect the mains cable to the cor-
rect terminals for your electrical sup-
ply type.
Check that the links are correctly fit-
ted and that the terminal screws are
tight. Secure the mains cable using
the cable clamp.
Current Operated Earth Leakage
Breakers
Where the installation is protected
by a 30 milliamp sensitivity residual
current device (RCD), the combined
use of your cooker and other do-
mestic appliances may occasionally
cause nuisance tripping. In these in-
stances the cooker circuit may need
to be protected by fitting 100mA de-
vice. This work should be carried
out by a qualified electrician.
35
Hotplate
Check each burner in turn. There is a
flame safety device that stops the
flow of gas to the burner if the flame
goes out. For each burner, turn the
control knob to the large flame sym-
bol. Press in the control knob. This
lets gas through to the burner. Keep
holding the knob pressed in and
press the igniter button or light with a
match. Keep holding the control knob
pressed in for about 10 seconds.
If when you let go of the control knob
the burner goes out, the safety device
has not held in. Wait one minute then
try again this time holding the control
pressed in for slightly longer.
Grill
Open the grill compartment door.
Turn on the grill control and check
that the grill heats up.
Oven check
The clock must be set to the time of
day before the ovens will work.
See the 'The clock' section for how
to set the time fo day.
At the same time, press - or + until
the correct time shows.
Don't forget it's a 24-hour clock.
If you make a mistake or press the
wrong button, turn off the power sup-
ply for a minute or two and start
again.
Turn on the oven and check that the
oven fan starts to turn and that the
oven starts to heat up. Turn off the
oven.
English