Installation
For best performance at high ambient temperatures, there must be free air
circulation over the cooling unit at the rear of the refrigerator.
Ensure that there is a free air space above the refrigerator and that the flue
(chimney) on top of the cabinet is not covered in any way. Do not place the
refrigerator in a space where air circulation is restricted. Follow "clearance"
instructions.
This free-standing refrigerator requires accessibility to the back for servicing the
gas equipment, which can be obtained by using a certified Flexible Metal
Connector to allow the refrigerator to be withdrawn without disrupting the gas
supply. "Where a flexible metal connector is used, it must comply with local
authorities and in Canada with the provisions of the current Standard CAN 1-
6.10, Metal Connectors for Gas Appliances". However, if the Local Authorities
require a rigid gas supply connector, the refrigerator should be located with
sufficient space at the back for servicing or, if located against a wall a removable
panel of a minimum size of 16" x 20" should be provided in the wall to allow
access to the rear of the refrigerator. If you purchased a CM (CO Monitor model)
you must follow instructions that were included with your CO detector.
Heat Shield
The heat shield must be installed before operating
the appliance. This is a CSA requirement.
Un-wrap the heat shield (located inside the box
along with the appliance). Mount heat shield with
the screws (supplied) to left side of the fridge. See
diagram.
Heat Shield
3