U G P 1 3
TROUBLESHOOTING INSTRUCTIONS &
SUGGESTED SPARE PARTS TO KEEP ON HAND
REFRIGERATOR DOES NOT COOL, CHECK LIKELY CAUSES:
Burner orifice clogged. Clean. See section M
1.
Item #2. Periodic Maintenance, Items 1-9.
Check to ensure refrigerator is level – (left to right and front to back)
2.
Restriction on airflow across cooling unit.
3.
Heavy frost build up on evaporator fins. Defrost.
4.
Flue baffle not inserted properly in flue tube.
5.
Improperly set thermostat. See paragraph on the thermostat. In hot weather or
6.
heavy use the setting should be closer to "Max" than usual.
Burner dirty. Clean. See Section M
7.
P
M
ERIODIC
AINTENANCE
LP gas pressure low at the burner. Regulator pressure must not drop below 11
8.
inches W.C (water column) on high fire. C
Burner not located properly under the flue tube. Relocate, the flame must be
9.
centered directly into the flue.
Burner damaged. Replace.
10.
Odours and fumes
11.
Dislocated burner
Damaged Burner
Dirty orifice
Dirty flue tube – C