Maintenance
..........................................................................................................................................................
All preventive maintenance activities must be performed on a regular basis. Performing routine
preventive maintenance actions can aid in providing safe, trouble-free operation of all FLUID
equipment.
FLUID is not responsible for performing regular inspection and maintenance actions for your
machines. Instruct all personnel in equipment inspection and maintenance actions and also in
accident reporting and recording.
Wipe and clean the Tank, Rails, and the Seat Wheels with clean water.
CAUTION
Do not use any chemical cleaner.
Item
Time Frame
Seat Rails and Wheels Weekly
Frame
Weekly
Tank Shell
Weekly
Tank and Water
12 months to 2 years
Treatment
Check every hundred
Bungee Cord
hours for correct tension
and for signs of wear.
Check every hundred
Rowing Belt
hours for correct tension
and for signs of wear.
Troubleshooting
..........................................................................................................................................................
Fault
Rower is in direct sunlight or
Water changes color or
has not had water treatment.
becomes cloudy.
Local tap water is of poor
quality.
Bungee not under enough
Rower Belt slipping off
tension.
Belt/ Bungee Pulley.
Recoil not strong enough.
Sensor gap
Inconsistent readings on
Faulty Sensor
the Monitor for 500meter
Sensor has moved out of
split time and SPM
position
(strokes per minute).
Wiring harness
The Monitor does not
Batteries installed incorrectly
illuminate after battery
or need replacing.
installation.
The Monitor screen
Loose or failed connection.
illuminates, but does not
Sensor gap too wide
register when rowing.
The Monitor LEVEL is not
Monitor LEVEL needs to be
synchronized with the
recalibrated.
Tank LEVEL.
Wipe down Side Rails and Seat Wheels with lint free cloth.
Wipe down Frame with lint free cloth.
Only use water and a clean cloth to wipe the Tank Shell.
Do NOT use any chemical cleaner to wipe the Tank Shell
Follow instructions as specified in the "Water Treatment Procedure"
section of this manual.
The Bungee Cord should last for many years. If a Bungee Cord change
is required, please contact your local service representative or go
online at www.fluid-eu.com for further details.
The Rowing Belt should provide many years of trouble free use.
If a Rowing Belt change is required, please contact your local service
representative or go online at www.fluid-eu.com for further details.
Probable Cause
Change Rower location to reduce direct exposure to sunlight.
Add Water Treatment or change Tank water as directed in
the Water Treatment section of this manual. Consider using
distilled water to refill Tank.
Tighten Bungee Cord following the instructions in "Reattaching
the Rower Belt" section of this
manual at "Step 5".
Use the battery cover of the Monitor as a "Gap Tool" to check
the gap between Sensor Head and Magnetic Ring, or see if the
Sensor Head has moved out of position.
Please contact your nearest FLUID customer service center for
details.
Replace/reinstall batteries in correct position and try again.
If the LCD screen fails to illuminate, try rotating the batteries
slightly in the Monitor.
If this fails, contact your local service center.
Check that the Monitor lead is connected properly. If it is
connected then contact your local service center. Check Sensor
gap.
Please refer to "Calibration Procedure" page 13 of this manual.