2.
Unscrew the 2 screws (2) of the
injector holder (1).
3.
Pull out the injector holder.
1
Injector holder
2
Screw
4.
Unscrew injector by turning to
counter-clockwise direction.
5.
Fit new injector.
Reduced flow adjustment for
the gas oven
For the appropriate functioning of the oven
re-checking the by-pass adjustment is
extremely important. In order to provide
maximum security to the user these
operations have to be done with care.
1.
Ignite the burner that is to be adjusted
and turn the knob to the high flame
position.
2.
Close the oven door and wait for 10
to 15 minutes until the oven becomes
ready for adjustment.
3. Take out the knob
4. After 15 minutes, adjust the oven to
the lowest flame position.
5. Set the flame length to 2 to 3 mm by
means of the screw 1 on the oven
tap. Turning the screw in clockwise
direction reduces the flame, turning it
anticlockwise increases the flame.
B CAUTION:
If the temperature of the oven
increases unintendedly, turn off the
oven and call the authorised service to
have oven thermostat repaired.