Blomberg BGR 24100SS Manuel D'utilisation page 20

Publicité

Les langues disponibles

Les langues disponibles

2.
Remove the knob from the gas tap.
3.
Use an appropriately sized
screwdriver to adjust the flow rate
adjustment screw.
For LPG (Butane - Propane) turn the
screw clockwise.
For the natural gas, you should turn the
screw counter-clockwise once.
» The normal length of a straight flame in
the reduced position should be 6-7
mm.
4.
If the flame is higher than the desired
position, turn the screw clockwise. If
it is smaller turn anticlockwise.
5.
For the last control, bring the burner
both to high-flame and reduced
positions and check whether the
flame is on or off.
Depending on the type of gas tap used
in your appliance the adjustment screw
1.
Open grill door.
2.
Unscrew fastening screw of the
burner.
3.
Slightly pull the grill burner (1) to lift
it free with its link(s) on the rear side
connected.
4.
Unscrew injector by turning to
counter-clockwise direction (3).
5.
Fit new injector.
K.-
jmmmmm-.'.i
1
Grill burner
2
Injector holder
3
Injector
Exchange injector for the oven
1.
Unscrew fastening screws of the
back wall.
1. Flow rate adjustment screw