Télécharger Imprimer la page

Blomberg BGR 24100SS Manuel D'utilisation page 18

Publicité

Les langues disponibles

Les langues disponibles

Test for Gas Leaks
Leak testing is to be conducted by the insta
Her according to the instructions given in
this section.
Turn on Gas.
Apply a non-corrosive leak
detection fluid to all joints and fittings in
the gas connection between the shut-off
valve and the range. Include gas fittings and
joints in the range if connections may have
been disturbed during installation.
Bubbles
appearing around fittings and connec¬
tions indicate a leak.
If a leak appears, turn off supply line gas
shut-off valve and tighten connections. Re¬
test for leaks by turning on the supply line
gas shut-off valve. When leak check is com¬
plete (no bubbles appear), test is complete.
Wipe off all detection fluid residue. Proceed
to Step 6: Final Steps on page 16.
A
CAUTION
Never check for leaks with a flame. Do not
continue to the next step until all leaks are
eliminated.
A
CAUTION
Before you plug in an electrical cord, be
sure all controls are in the OFF position.
Test burner function
1. Turn on Power at Breaker
If display screen flashes and beeps con¬
tinuously, the wiring is incorrectly installed.
Verify that wiring in house is correctly
installed. If so, call Service.
2. Test Rangetop Burners
Test Burner Ignition. Select a rangetop
burner knob. Push down and turn to the
flame symbol. The ignitor/spark module
will produce a clicking sound. Once the air
has been purged from the supply lines, the
burner should light within four (4) seconds.
Test Flame: High Setting. Turn burner on to
HI. See figure 7 for appropriate fiame char¬
acteristics. If any of the burners continue
to burn mostly or completely yellow, call
Blomberg Service.
Test Flame: Low Setting. Turn burner on to
L.O. Verify that the flame completely sur¬
rounds the burner. There should be a flame
at each burner port and there should be no
air gap between the flame and the burner.
If any of the burners do not carry over, call
Service.
Test the ignition and flame of each rangetop
burner as described above.
When flame is properly adjusted
There should be a flame at each range top
burner port.
There should be no air gap between the
flame and the burner port.
3. Test Oven Burners
Remove the oven bottom cover. Remove
the two rear thumb screws, slide cover
forward and out.
Test Bake Burner Ignition.
Set the oven
to bake at 350° F. After 30-75 seconds,
the burner will ignite. The burner wiil stay
lit until the 350° F is reached and then shut
off. From this point forward, the burner will
cycle on and off to maintain the tempera¬
ture.
Test Bake Burner Flame,
While the
burner is lit, inspect the flame. See below
flame figures for proper flame characteris¬
tics. If the flame burns completely or mostly
yellow, adjust the bake burner air shutter.
See below flame figures (next page) for
details.
Test Broil Burner Ignition.
Set cooking
mode to Hi Broil. The burner will ignite after
30-75 seconds.
Test Broil Burner Flame.
While the burner

Publicité