death or serious burns to children and
adults.
A
DANGER:
Electrical shock
hazard!
•
Use extreme caution when drilling
holes into the wall or floor. There may
be concealed electrical wires located
behind the wall or under the floor.
•
Identify the electrical circuits that
could be affected by the installation
of the Anti Tip Device, then turn off
power to these circuits.
Failure to follow these instructions
may result in electrical shock or
other personal injury.
Connection to the gas supply
This appliance has been tested
in accordance with the following
standardas:
•
ANSI Z21.1 Standard for
Hoousehold Cooking Appliances
(USA)
•
CAN 1.1 M81 Interim Reqt no 58
Domestic Cooktops (CANADA).
•
CAN/ CSA-C 22.2 No 61-M89
Household Cooking Ranges.
In Canada, installation must be in
aocordance with CAN 1-B149.1 and
2 Installation Codes for Gas Burning
Applianoes and or local codes.
For Massachusetts Installations:
1. Installation must be performed by
a Qualified or licenced contactor,
plumber or gas fitter qualified or
licenced by the state , province or
region where this appliance is being
installed.
2. Shut-off valve must be a "T" handle
gas cock.
3. Flexible gas connector must not be
longer than 36 inches.
High Altitude Installation note:
This cooker is ETL certified for safe
operation up to an altitude of 10.000 ft.
without any modifications.
Exception: for use with LR the range
must first be converted using the LP
conversion instructions included in this
literature package.
Connect to the gas suply
Important note for LP users
The range is shipped from the factory for
use with natural gas. For use with propane
(LP) gas, your range must first be converted
using tthe LP conversion kit.
The gas connection is located below the
back panel of the range (see fig). It is
accessible through the warming drawer
access panel or from the back of the range.
To reach access panel, remove warming
drawer.
Shut off main gas supply valve before
disconnecting the old range and leave it off
until the new hook-up has been completed.
The cooker can be installed using rigid
pipe or a CSA, cCSAus, UL International-
certified flexible metal appliance connector.
If using a flexible connector, always use a
new connector.