SYMPTOM
Main burner goes
Pilot fl ame is not large
out; pilot stays on.
enough or not engulfi ng
the thermopile.
Thermopile shorting.
Remote wall switch wire
is too long; too much
resistance in the system.
Faulty thermostat or
switch.
Main burner goes
Refer to "MAIN BURNER
out; pilot goes
GOES OUT; PILOT
out.
STAYS ON"
Vent is blocked
Vent is re-circulating
Flexible vent has become
disconnected from fi replace.
Pilot goes out
System is not correctly
when the gas
purged.
knob is released.
Out of propane gas.
The gas valve
Pilot fl ame is not large
has an interlock
enough.
device which
will not allow
Pilot fl ame is not engulfi ng
the pilot burner
the thermocouple
to be lit until the
Thermocouple shorting /
thermocouple
faulty.
has cooled. Allow
approximately 60
seconds for the
Faulty valve.
thermocouple to
cool.
Pilot burning;
Thermostat or switch is
no gas to main
defective
burner; gas
Wall switch wiring is
knob is on 'HI';
defective.
wall switch /
thermostat is on.
Main burner orifi ce is plugged.
Faulty valve.
Pilot will not light.
No spark at pilot burner.
PILOT
BURNER
THERMOPILE
THERMOCOUPLE
Out of propane gas.
Spark gap is incorrect.
No gas at the pilot burner.
PROBLEM
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
TEST SOLUTION
Turn up the pilot fl ame.
Replace pilot assembly.
Clean thermopile connection to the valve. Reconnect.
Replace thermopile / valve.
Shorten wire to connect length or wire gauge.
Replace.
Check for vent blockage.
Check joint seals and installation
Re-attach to fi replace.
Cap was not replaced.
Purge the gas line.
Fill the tank.
Turn up the pilot fl ame.
Gently twist the pilot head to improve the fl ame
pattern around the thermocouple.
Loosen and tighten thermocouple.
Clean thermocouple and valve connection.
Replace thermocouple.
Replace valve.
Replace.
Connect a jumper wire across the wall switch terminals;
if main burner lights, replace switch / thermostat.
Disconnect the switch wires & connect a jumper
wire across terminals 1 & 3; if the main burner lights,
check the wires for defects and / or replace wires.
Remove stoppage in orifi ce.
Replace.
Check if pilot can be lit by a match.
Check that the wire is connected to the push button igniter.
Check if the push button igniter needs tightening.
Replace the wire if the wire insulation is broken or frayed.
Replace the electrode if the ceramic insulator is cracked or broken.
Replace the push button ignitor
Fill the tank.
Spark gap should be 0.150" to 0.175" (5/32" to 11/64" approx.)
from the electrode tip and the pilot burner. To ensure proper
electrode location, tighten securing nut (fi nger tight plus 1/4 turn).
Check that the manual valve is turned on.
Check the pilot orifi ce for blockage.
Replace the valve.
Call the gas distributor.