8.11 LOW BATTERY / MANUAL BYPASS
The life span of the remote batteries depends on various factors: quality of the
batteries, the number of ignitions, the number of charges to the room thermostat set
point, etc.
When the transmitter batteries are low, a Battery Icon will appear on the LCD
display before all battery power is lost. When the batteries are replaced this icon will
disappear.
Not applicable when plugged into 110V.
When the receiver batteries are low, no "beep" will be emitted from the receiver
when it receives an ON/OFF command. This in an alert for the receiver that there's low battery. When the
batteries are replaced the "beep" will be emitted from the receiver when the ON/OFF key is pressed.
If the batteries of the receiver or transmitter are low, the appliance can be turned on manually by sliding the
three position slider switch on the receiver to the "ON" position. This will bypass the remote control feature and
the appliance main burner will come on if the gas valve is in the "ON" position.
8.12 IN THE EVENT OF A POWER FAILURE
If the receiver is equipped with batteries they will enable fl ame height control, ON/OFF or thermostat
function to control the fi replace during a power failure. Refer to "APPLIANCE OPERATION" section when
communications between receiver and transmitter have been lost. The will receiver emit a "beep" sound to
confi rm programming has been successful once power is restored. During a power failure, if the fi replace was
on, the fl ame height will stay at the setting prior to the failure. If off when the failure occurs and then turned on,
the fl ame height will come on at "HI". The fl ame height can then be controlled by the remote.
8.13 FAN CONTROL MODULE
Control module offers the added ability to control the fan
speed through six (6) speeds, a remotely actuated 120V
AUX outlet for the NIGHT LIGHT™ and a constantly
powered 120V outlet.
NOTE: Control module ON/OFF switch should always
be in the "ON" position. If for any reason the module
is turned "OFF", the components plugged into the
module won't have power.
8.14 TIMED BLOWER
Your remote system may have a built in timer (in thermostat mode) that enables the blower (if equipped) to
cycle on and off automatically when the burner turns on and off. With the remote control fan speed preset at
the preferred speed, the blower will come on approximately 5 minutes after the main burner comes on and will
shut off approximately 12 minutes after the burner shuts off.
This time delay is designed to maximize the blower distribution of heated air.
If at any time the burner re-ignites before the twelve minutes are over, the fan will continue to run.
NOTE: At any time in the sequence, the blower (if equipped) can be manually turned on/off using the
remote control.
W415-0748 / C / 08.20.12
ON
35.13
35.14
120V AUX OUTLET
FAN OUTLET
CONSTANTLY POWERED
120V OUTLET
35.15
35.19B
76
°F
MAINS VOLTAGE
SUPPLY CORD
MODULE ON/OFF
SWITCH (SHOWN IN
THE ON POSITION)
COMMUNICATION
BUS (3 PIN)