Télécharger Imprimer la page

Napoleon GD82NT-PA Instructions D'installation Et D'utilisation page 45

Publicité

10.3 VENTURI ADJUSTMENT
This appliance has an air shutter that has been factory set open according
to the chart below:
Regardless of venturi orientation, closing the air shutter will cause a more
yellow flame, but can lead to carboning. Opening the air shutter will cause a
more blue flame, but can cause flame lifting from the burner ports. The
flame may not appear yellow immediately; allow 15 to 30 minutes for the
final flame colour to be established.
AIR SHUTTER ADJUSTMENT MUST ONLY BE DONE BY A QUALIFIED
INSTALLER!
10.4 FLAME CHARACTERISTICS
It's important to periodically perform a visual check of the pilot and
burner fl ames. Compare them to the illustrations provided. If any fl ames
appear abnormal call a service person.
VENTURI
BURNER
ORIFICE
49.1
AIR SHUTTER OPENINGS
LP
NG
3/8" - 1/2"
FLAME MUST
ENVELOP UPPER
3/8" TO 1/2" OF
THERMOCOUPLE &
THERMOPILE
54.2
W415-0748 / C / 08.20.12
45
AIR
SHUTTER
OPENING
1/2"
1/16"

Publicité

loading

Ce manuel est également adapté pour:

Gd82pt-pa