Installation
Alternatively:
4. Connection to a permanently installed cable:
a. Note that according to VDE 0700, an all-pole disconnecting device with a contact opening width of
≥ 3 mm per phase should be provided at the installation end.
b. The cross-section of the cable must meet the requirements of the minimal cross-section, as mentioned in
chapter "Technical specifications". The maximum applicable cross-section is 6 mm
c. Open the cover.
d. Dismount the pre-installed connection cable.
e. Route the permanently installed cable through the grommet and connect it as shown in the circuit dia-
gram. Make sure that the grommet fits tightly around the cable to ensure optimal protection against water.
f. Refit the cover on the appliance.
The earth conductor must be connected!
MBH 3 (230 V)
Fig. 7: "Circuit diagram"
MBH 4 (230 V)
25
.
2
MBH 6 (230 V)
CLAGE
EN
MBH 7 (400 V)