To activate this function:
Press
(14)
Repeat the operation to deactivate.
Note: if during automatic operation are selected from the
Selection bar (3) the speeds from 1 to 3, the automatic
operation is interrupted;
if, instead, the Power Boosters are selected, automatic
operation will resume at the end of the timing, while in the
meantime the symbol "
Note: if the hob automatically shuts down with Automatic
mode active, the extractor fan will automatically turn off in a
gradual manner.
Filter saturation indicator
The hood indicates when filter maintenance is needed:
Carbon/ceramic odour filters
"
"(13) comes on
Grease filter
"
"(13) flashes
Note: this function is disabled by default (see how to
enable it in the paragraph "Activation filter saturation
indicator")
Reset filter saturation
After performing maintenance on the filters (greases and/or
carbon/ceramic), press and hold "
"
"(13) turns off, restarting the indicator count.
Activation filter saturation indicator
This indicator is normally deactivated.
To activate it, proceed as follows:
- turn on the extractor hob via
- with the extraction motor and cooking zones off, press the
Selection zone (12)
- long press "
" (11) until the letters "F" – "G"
appear alternately flashing in the Display (12)
F = carbon/ceramic odour filters
G = grease filter
Carbon/ceramic odour filters
−
press on the Display (12) when the letter "F" appears
−
press "
" (13) – flashing light
−
long press "
activation of the carbon/ceramic odour filter indicator
Grease filter
−
press on the Display (12) when the letter "G" appears
−
press "
" (13) – fixed light
" remains flashing.
" (13) ;
;
" (11) again to confirm the
−
long press "
of the grease filter indicator
The device can also be used in combination with a
Window sensor KIT (not supplied by the manufacturer).
If the Window sensor KIT is installed (only in the case of use
in EXTRACTOR mode), air extraction will halt every time the
window in the room, on which the KIT is applied, is closed.
-
The KIT must be electrically connected to the device
by qualified and specialised technical personnel.
-
The KIT must be certified separately in accordance
with the safety standards for the component and its
use with the device. Installation must be carried out
in accordance with current regulations for domestic
systems.
PLEASE NOTE:
-
the wiring of the KIT to be connected to the device
must be part of a certified safety extra-low voltage
(SELV) circuit.
-
the manufacturer of this device declines all liability
for any inconvenience, damage or fires caused by
defects and/or problems associated with the
malfunction and/or incorrect installation of the KIT.
63
" (11) again to confirm activation