B. Ignition failure, no white smoke at the air outlet during ignition, E1 alarm
(nozzle, air pipe and oil pipe are not blocked).
1. Please check whether the solenoid valve is damaged, or the solenoid valve
power line is damaged
C. The ignition is successful, and there is no white fog and smoke at the air outlet
during ignition, but the machine E1 alarms.
1. Please check the bright resistor (photo resistance), clean the oil stain on the
surface of the bright resistor, or replace the bright resistor (photo resistance).
D. E2 alarm.
1. Please check whether the temperature sensor probe is damaged, whether
the plug of the temperature sensor probe is plugged or in poor contact.
E. E3 alarm (voltage alarm).
1. Please check the input voltage (machine alarm when the voltage is lower
than 168V).
3.4.
a)
Pull the mains plug and let the unit cool down completely before cleaning,
adjusting or replacing accessories and when the unit is not in use. Wait until
the rotating parts stop.
b)
Use only non-corrosive cleaning agents for cleaning the surfaces.
c)
Store the unit in a dry and cool place protected from moisture and direct
sunlight.
d)
Do not spray the unit with a stream of water or immerse it in water.
e)
Make sure that no water enters through the ventilation openings in the casing.
f)
Clean the ventilation openings with a brush and compressed air.
g)
Perform regular inspections of the unit checking technical fitness and any
damages.
h)
Use a soft cloth for cleaning.
i)
Do not use sharp and/or metal objects (e.g. wire brush or metal spatula) for
cleaning as they may damage the surface of the appliance material.
j)
Do not store fuel in an unused unit for more than 2 months.
k)
In the case of regular use (8-10 hours a day), clean the unit:
•
Once a month - the ignition electrodes and the combustion chamber.
Every six months - the fuel tank.
•
Cleaning and maintenance
EN