Maintenance
Regular maintenance work
The Geberit HS30 and HS50 hygienic flush units
are low-maintenance.
Recommendation: carry out the
maintenance work described below once a
year.
The Geberit Control app displays when the next
maintenance is due. After the maintenance work
has been carried out, the maintenance interval
must be reset in the Geberit Control app.
Checking the fill valve and flush
valve
1
Check the fill valve function.
2
Check the flush valve function.
3
If necessary, perform maintenance work as
outlined in the maintenance manual for the
fill valve or flush valve.
Checking the overflow pipe
1
Check the flush valve overflow pipe for
scaling.
2
Descale the overflow pipe if necessary.
18014409509155339 © 04-2024
971.559.00.0(02)
Checking the solenoid valve unit
Press the <Test> button on the control unit.
✓ The solenoid valves are opened one after
another for 5 seconds.