Operation
Display of operating state
The operating state of the Geberit HS30 and HS50 hygiene flush units in concealed cistern is displayed on
the control unit. The control unit is accessible once the actuator plate has been detached.
TEST
971.368.00.0(00)
Figure 2: Displays and controls on the control unit
1
Status LED
2
<Test> button
3
Buzzer
Table 1: Displays and controls
Element
Status LED
<Test> button
3)
Buzzer
1) Only when connected to GEBUS, → see Geberit Connect system manual
2) When the button is pressed, the hygiene flush unit is highlighted in the Geberit Control app under [My end devices].
3) The buzzer is deactivated ex works. It can be reactivated in the Geberit Control app if required.
4) The buzzer can be suppressed by pressing the <Test> button.
18014409509155339 © 04-2024
971.559.00.0(02)
Status
Off
Lights up green
Flashes green
Lights up orange
Lights up red
Flashes green/red
Press button for < 5 s
Press button for > 5 s
Off
4)
On
Beeps every second
Meaning
• No operating voltage
• Normal operation
• Solenoid valve open
• Warning, diagnose with Geberit Control app
• Addressing via GEBUS pending
• Malfunction, diagnose with Geberit Control app
• Basic settings not configured
• Localisation of the hygiene flush unit
• Solenoid valve test: after releasing the button, the
solenoid valves open one after the other for 5 s
• When the solenoid valve test is active: cancel test
• In the event of an active malfunction: suppress
buzzer
• Identification of the hygiene flush unit
• Pair with the Geberit Control app
• Normal operation
• Buzzer deactivated
• Malfunction, diagnose with Geberit Control app
• Localisation of the hygiene flush unit
EN
1)
1)
2)
1)
17