Télécharger Imprimer la page

Geberit GIS Manuel D'entretien page 18

Masquer les pouces Voir aussi pour GIS:

Publicité

EN
Geberit Control app
The Geberit Control app is available for commissioning, making settings and malfunction diagnosis. The app
communicates with the device via a Bluetooth® interface.
The Geberit Control app is available free of charge for Android and iOS smartphones in the respective app
stores.
Rectifying malfunctions
Malfunctions during operation are indicated by the control unit displays. The malfunction diagnosis is carried
out with the Geberit Control app. The faults are also displayed in the app (highlighted in red or orange).
Malfunction
No flush actuation, status
LED off
No flush actuation, status
LED lights up green
Status LED lights up
orange
Status LED lights up red
1)
and buzzer on
1) Serious faults such as backpressure are always indicated by the buzzer. Other faults are only displayed if the buzzer
is activated in the <Device settings> menu.
18
Cause
Operating voltage inter-
rupted
• No flushing programme
active
• Solenoid valve
defective
• Control unit defective
Warning:
e.g. maintenance interval
expired
Malfunction:
e.g. volumetric flow rate
sensor defective
Remedy
▶ Check the mains voltage.
▶ Check the power supply unit.
▶ Check flushing programmes with Geberit Control
app.
▶ Test solenoid valve with the <Test> button.
▶ Replace the control unit.
▶ Read out malfunction message with Geberit
Control app.
▶ Rectify malfunction according to instructions in the
Geberit Control app.
▶ Read out malfunction message with Geberit
Control app.
▶ Rectify malfunction according to instructions in the
Geberit Control app.
18014409509155339 © 04-2024
971.559.00.0(02)