OPERATION
DATA CENTER
See Figure 11.
Push the mode button to cycle through the data display
modes.
Voltage: Displays current voltage output.
Frequency (Hz): Displays power output frequency in Hertz.
Lifetime Hours: Displays the lifetime run hours.
Fuel Level: Indicates how much gasoline remains in the
fuel tank.
Run Time/Maintenance: Displays current run time. Resets
to zero when shut down. Maintenance reminder displayed
when required.
Maintenance Codes:
P25 - Change engine oil
P50 - Clean air filter, Change engine oil
P100 - Change engine oil, clean air filter, replace fuel
filter
BREAK-IN PERIOD
For proper break-in, do not exceed 50% of the rated running
watts during the first five hours of operation.
Use supplied oil until first recommend oil change. Do not
use full synthetic oil during break in period. Full synthetic oil
may prevent proper breaking and seating of the piston rings.
Vary the load occasionally to allow stator windings to heat
and cool and help seat the piston rings.
BEFORE STARTING THE GENERATOR
Verify that:
l The generator is placed in a safe, appropriate location.
l The generator is on a dry, flat, and level surface.
l Oil and fuel levels are within safe operating range.
l All loads are disconnected from the control panel recep-
tacles.
l The ECO mode switch is in the OFF position.
DANGER
NOT move or tip the generator during operation.
STARTING THE GENERATOR
See Figures 12 - 14.
l Place the generator in a safe, appropriate location.
l Unplug all loads.
l Make sure the ECO mode switch is in the OFF position.
l Check oil and fuel levels. If needed, add fuel or oil as
described earlier.
l Turn the vent knob on the fuel cap to the ON position.
Fire and explosion hazard. DO
FIG. 11
A
C
E
A - Voltage
B - Power Output
C - Lifetime Hours
D - Fuel Level
E - Run Time/Maintenance Reminder
F - Mode Button
FIG. 12
B
A - Vent Knob
B - On
C - Off
F
B
D
A
C
English | 17