Télécharger Imprimer la page

GYS TITAN 321 DC TRI Mode D'emploi page 39

Publicité

Les langues disponibles
  • FR

Les langues disponibles

User manual
MMA (SMAW) WELDING MODE
INSTALLATION AND GUIDANCE
• Plug the cables, electrode holder and earth clamp into the plug connections.
• Respect the electrical polarities and the strength of the welding power indicated on the electrode boxes.
• Remove the coated electrode from the electrode holder when the welding power source is not in use.
• The equipment is fitted with 3 inverter-specific features:
- Hot Start provides an overcurrent at the beginning of the welding process.
- Arc Force creates an overcurrent which prevents the electrode from sticking to the weld pool.
- The Anti-Stick technology makes it easier to unstick the electrode from the metal.
MMA WELDING PROCESSES
• Standard
This welding method is suitable for most applications. It is suitable for welding
with all types of coated, rutile, basic and cellulosic electrodes and on all mate-
rials: steel, stainless steel and cast iron.
Recommendations:
- Use low Hot Start for thin sheets, and high Hot Start for thicker sheets and diffi-
cult metals (dirty or oxidised parts).
- The Arc Force can be adjusted from -10 to +10 It should be considered in
conjunction with the choice of electrode type selected in the Advanced Menu
(see Advanced Menu).
Adjustable values
Electrode types
HotStart
Rutile
0 - 100 %
Basic
Cellulosic
The selection of the electrode type is in the welding cycle, after current setting
( ).
Rut.
Bas.
rod
Cel.
• Pulse
This welding mode is recommended for applications in a vertical upright position
(PF). Pulsing keeps the weld pool colder while still promoting material transfer.
Without pulsing, vertical rising welds require a «fir tree» movement, i.e. a challen-
ging triangular movement. With MMA Pulse, this movement is not necessary, and
depending on the thickness of your workpiece, a straight upward movement may
be sufficient. However, if you want to enlarge your weld pool, a simple sideways
movement similar to flat welding will be adequate. If this is the case, you can set
the frequency of your pulse current on the display. This process offers greater
control of vertical welding tasks.
Recommendations:
- Use low Hot Start for thin sheets, and high Hot Start for thicker sheets and diffi-
cult metals (dirty or oxidised parts).
- The Arc Force can be adjusted from -10 to +10 This should be considered in
combination with the electrode type selected in the Advanced Menu (see below).
Adjustable values
Electrode
types
HotStart
Arc Force
Rutile
0 - 100 %
Basic
-10 > +10
Cellulosic
Rut.
Bas.
rod
Cel.
Translation of the original
instructions
Arc Force
-10 > +10
Rutile
Basic
Cellulosic
Cold current
Pulse frequency
+20 > +80%
0.4 - 500 Hz
Rutile
Basic
The selection of the electrode type is in the welding cycle, after current setting ( ).
Cellulosic
TITAN 231 DC FV / 321 DC TRI
SETUP
PRESS 3''
The grayed-out areas are not available in this mode.
SETUP
PRESS 3''
The grayed-out areas are not available in this mode.
Weld
JOB
Weld
JOB
39

Publicité

loading

Ce manuel est également adapté pour:

Titan 231 dc fv