Télécharger Imprimer la page

DAB FEKA VS GRINDER Instructions Pour L'installation Et La Maintenance page 13

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 14
Fig. 8
10.2. Changing the grinder
See Fig.9 at the end of the booklet
10.3. Cleaning the impeller
See Fig.10 at the end of the booklet
11. TROUBLESHOOTING
FAULTS
CHECKS (possible causes)
The motor does not start
Check that voltage is reaching the motor.
and does not make any
Check the protection fuses.
noise.
The float switch does not allow starting.
The pump does not
The suction grid or the pipes are blocked.
deliver.
The impeller is worn or blocked.
If installed on the delivery pipe, the check valve is locked in the
closed position.
The liquid level is too low. At start-up, the water level must be
higher than the filter level.
The head required is higher than the pump's characteristics.
The pump does not stop. The float does not interrupt pump operation.
The
flow
rate
is
Check that the suction grid is not partially blocked.
insufficient.
Check that the impeller or the delivery pipe are not partly blocked
or encrusted.
Check that the impeller is not worn.
Ensure that the check valve (if contemplated) is not partially
blocked.
Check the direction of rotation in three-phase versions (See
paragraph "CHECKING THE DIRECTION OF ROTATION").
The thermal overload
Check that the fluid to be pumped is not too dense as it would
protection device stops
cause overheating of the motor.
the pump.
Check that the water temperature is not too high (see liquid
temperature range).
The pump is partially blocked by impurities.
The pump is mechanically blocked.
Impeller blocked.
The pump does not start.
Absorption higher than
Impeller blocked.
data plate values.
Check the direction of motor rotation in the three-phase version.
The pump is noisy
Check that the knife rotates freely.
ENGLISH
10.1. Checking and changing seal oil
• Slacken and remove the 3 screws (1) and lift the pump base (2).
• Use pliers to hold the grinder head and slacken it and remove the screw (3).
• Remove the grinder head (4). Take the impeller (5) off the shaft.
• Retrieve the tab, the sand guard ring (8) and the two fixing half-rings.
Slacken and remove the 4 body screws and lift off.
• Now turn the pump upside down, unscrew and remove the cap (6). Tilt the pump
so as to drain the oil out of the hole of the cap (6) and pour it into a container.
• Analyse the oil: if it contains water or abrasive particles (e.g. sand), check
the condition of the mechanical seal (7) and replace it if necessary (at a
specialised centre).
• In the latter case also replace the oil with approx. 170 g of oil type
MARCOL 152 ESSO.
• Restore the oil level inside the seal oil chamber by means of a special
funnel inserted in the hole of the cap (6).
Screw the cap (6) back into its seat and carry out the disassembly
operations in reverse order to reassemble the pump after having applied a
suitable amount of Teflon grease in the seat of the sand guard ring (8).
USED OIL MUST BE DISPOSED OF IN ACCORDANCE WITH CURRENT
REGULATIONS.
10.4. Adjusting the impeller clearance
Proceed as follows:
1. Completely slacken the fixing screws.
2. Tighten the screws gently.
3. Tighten the retaining screws gently.
4. Slacken the screws by at least three turns.
5. Tighten the fixing screw by 180°.
6. Tighten the screws with a torque of 7 Nm.
11
REMEDIES
If burnt out, change them.
- Check that the float can move freely.
- Check that the float is efficient. (contact
the supplier).
Remove the obstructions.
Replace the impeller or remove the
obstruction.
Check the proper operation of the valve and
replace it if necessary.
Adjust the cable length of the float switch.
(See
paragraph
"ADJUSTING
FLOATING SWITCH").
- Check that the float can move freely.
- Check the efficiency of the float (contacts
may be damaged - contact the supplier).
Remove any obstructions.
Remove any obstructions.
Change the impeller.
Accurately clean the check valve.
Invert two power supply wires.
Clean the pump thoroughly.
Check for sliding between moving and fixed
parts; check the wear condition of the
bearings (contact the supplier).
Remove the obstruction, wash and clean;
contact DAB Service if necessary.
Remove the obstruction, wash and clean;
contact DAB Service if necessary.
Invert the two power supply wires.
Apply to the DAB assistance service.