22
Operation
While in TIG welding modes; It is used to select one of the 2-Position, 4-Position, Tailstock Position
EN
Trigger Mode and Electrode Type Selection Button
modes.
When 2-position is selected, led 10 lights up.
When 4-position is selected, led 11 lights up.
When the tailstock position is selected, led 12 lights up.
9
While in MMA mode; It is used to select one of the rutile, basic, cellulosic electrode modes.
When the rutile electrode is selected, led 10 lights up.
When the basic electrode is selected, led 11 lights up.
When cellulosic electrode is selected, led 12 lights up.
Led 14 lights when flat DC TIG is selected and led 15 lights when PULSE DC TIG is selected.
Button is for selecting flat DC TIG / PULSE DC TIG
When PULSE DC TIG is selected, its led 15 lights.
13
It is used to select the TIG parameter to be adjusted. After the related TIG parameter's led is on, the
TIG Parameters Selection Buttons
parameter is adjusted to the desired value with the parameter setting button.
You can set the following TIG parameters:
18 Pre-Gas Flow Time Led
19 Starting Current Led
20 Up-Slope Time Led
21 Main Current Led
22 Base Current Led
16-17
23 Pulse Duty Cycle Led
24 Pulse Frequency Led
25 Down Slope Time Led
26 Final Current Led
27 Pos-Gas Flow Time Led
28 Spot Welding Time Led
USER MANUAL
ID 300 T DC PULSE / ID 300 TW DC PULSE
www.magmaweld.com