Performance Data
Important Notice: Read performance data and compare the
capabilities of the system with your actual water treatment
requirements. It is recommended that the supply water be tested,
before installing a water treatment system, to determine your water
treatment needs.
Test Conditions
Flow Rate
F1000-DFB .................................................... = 0.75 gpm (2.83 L/min)
F1000-B1B .....................................................= 0.60 gpm (2.27 L/min)
Filter Capacity
F1000-DFB ....................................................... = 750 gallons (2839 L)
F1000-B1B ........................................................ = 750 gallons (2839 L)
Inlet Pressure ............................................................= 60 psi (4.1 bar)
Temperature .........................................= 68°F +/- 5°F (20°C+/- 2.5°F)
Testing was performed under standard laboratory conditions, actual
performance may vary.
Operating Requirements for F1000-DFB and F1000-B1B Systems:
Pressure ................................................. = 40-100 psi (2.75–6.89 bar)
Temperature ................................................. = 40-100°F (4.4–37.8°C)
F1000-DFB System Installed With FDF1-RC
Filter Cartridge
This system have been tested according to NSF/ANSI 42 for
reduction of the substances listed below. The concentration of the
indicated substances in water entering the system was reduced to
a concentration less than or equal to the permissible limit for water
exiting the system, as specified in NSF/ANSI 42.
Model F1000-DFB
Max. Permissible
Influent Challenge
Substance
Product Water
Concentration
Concentration
Standard 42
Chlorine
2.0 mg/L±10%
Taste & Odor
Flow Rate = 0.75 gpm (2.8 L/min); Capacity = 750 gallons (2839 L) or
12 months
Testing was performed under standard laboratory conditions, actual
performance may vary.
The Model F1000-DFB is Tested and Certified by
NSF International against NSF/ANSI Standard 42
C
US
and CSA B483.1 for the reduction of substances
specified on the Performance Data Sheet.
Reduction
Minimum
Average
Requirements
Reduction
Reduction
≥50%
88.8%
FRESHPOINT F1000-DFB, F1000-B1B Filtration Systems Instruction Manual • 9
F1000-B1B System Installed With F1B1- RC
Filter Cartridge
This system has been tested according to NSF/ANSI 42 and 53 for
reduction of the substances listed below. The concentration of the
indicated substances in water entering the system was reduced to
a concentration less than or equal to the permissible limit for water
exiting the system, as specified in NSF/ANSI 42 and 53.
Model F1000-B1B
Max. Permissible
Influent Challenge
Substance
Product Water
Concentration
Concentration
Standard 42
Chlorine
Taste &
2.0 mg/L±10%
Odor
Particulates
at least 10,000
(0.5-<1uM)
particulates/mL
Class 1*
Standard 53
Cysts **
Minimum 50,000/L
Atrazine
0.009 mg/L ± 10%
0.003 mg/L
Lead (pH 6.5) 0.15 mg/L ± 10%
0.010 mg/L
Lead (pH 8.5) 0.15 mg/L ± 10%
0.010 mg/L
Flow Rate = 0.6 gpm (2.2 L/min); Capacity = 750 gallons (2839 L) or 12 months
Testing was performed under standard laboratory conditions, actual
performance may vary.
* Reduces particles as small as 0.5-1 micron in size by mechanical means
** NSF/ANSI Standard 53 certified to reduce cysts such as Cryptosporidium
and Giardia by mechanical means.
The Model F1000-B1B is Tested and Certified by
NSF International against NSF/ANSI Standard 42,
53, and CSA B483.1 for the reduction of substances
C
US
specified on the Performance Data Sheet.
EPA Est. 082989-CHN-001
Reduction
Minimum
Average
Requirements
Reduction
Reduction
≥50%
95.9%
>85%
97.9%
99.95%
99.97%
99.99%
90.5%
93.7%
99.3%
99.9%
99.3%
99.6%