Filter Cartridge Replacement
NOTE: The life of the filter cartridges depends on water volume
used and the quality of the feed water. It is recommended that the
filter cartridges be replaced every 6-12 months, or when there is a
noticeable change in taste, odor, or flow of filtered water.
Ensure the correct cartridge is purchased for the system.
Model F1000-DFB uses FDF1-RC Replacement Cartridge
Model F1000-B1B uses F1B1-RC Replacement Cartridge
8. Cartridge Replacement
A. Relieve pressure by turning off the water supply to the system
and opening a faucet until water flow stops. Place a bucket or
towel under the system to catch any water drips (Figure 8a).
B. Lift the locking bar upward until the filter cartridge disengages
from the filter head assembly (Figure 8b).
C. Pull the cartridge away from the filter head assembly and ensure
the locking bar remains in the fully up position (Figure 8c).
D. Align the posts on the filter cartridge with the ports in the filter
head assembly. Slide the cartridge filter towards into the filter
head assembly engaging with the locking bar causing it to drop
forward and down. (Figure 8d).
E. Pull down the locking bar until it snaps into place (Figure 8e).
NOTE: See Placing the System into Operation section for remaining
steps.
Troubleshooting
Leaks between filter head assembly and filter cartridge
1. Relieve pressure by turning off the water supply to the system
and opening faucet until water flow stops. Place a bucket or
towel under the system to catch any water drips.
2. Remove cartridge and inspect O-rings to make sure they are
seated and clean.
3. Install filter cartridge. Place system into operation and check
for leaks. If leaks persist, turn off the water supply and contact
Technical Support at 1-800-279-9404.
Leaks from tubing fittings
1. Relieve pressure by turning off the water supply to the system
and opening faucet until water flow stops. Place a bucket or
towel under the system to catch any water drips.
2. Depress collet on system or inlet supply adapter tubing fittings
and pull tubing from fitting. Inspect surface of tubing for
scratches or debris. Clean or cut back tubing to access clean
surface.
3. Wet the end of the inlet tubing and press into the inlet fitting
of the system. Ensure the tubing is fully pushed past the fitting
O-rings. Place system into operation and check for leaks. If leaks
persist, turn off the water supply and contact Technical Support
at 1-800-279-9404.
8a
or
8b
8d
FRESHPOINT F1000-DFB, F1000-B1B Filtration Systems Instruction Manual • 7