Installation continued
5. Connecting the Faucet to the System
A. Determine the length of plastic blue tubing needed to connect
to the outlet (right) side of the filter from the faucet. Be sure
to allow enough tubing to prevent kinking and cut the tubing
squarely. Use a marker to mark one end of the tubing 5/8" from
the end (Figure 5). Wet the end of the 3/8" tube and push into the
outlet (right) connection of the system up to the mark.
CAUTION: Do not bend or crimp tube inserting.
B. Gently pull back on the tube to ensure it is connected properly.
6. Connecting the Supply Adapter
A. Determine the length of plastic white tubing needed to connect
the inlet (left) side of the filter with the feed adapter installed
on the cold water supply line. Be sure to allow enough tubing to
prevent kinking and cut the tubing squarely. Place a mark 5/8"
from one end of the tubing. Wet the end of the tubing. Insert the
end of the tubing into the 3/8" fitting of the inlet supply adapter.
The 5/8" mark should be flush with the collar of the fitting
located on the inlet supply adapter (Figure 6a).
B. Mark the remaining end of the tubing. Use a marker to mark 5/8"
from the end. Wet the end of the tube. Insert the end into the
feed connection on the inlet side (left) of the system. The tube
should go in up to the mark. (Figure 6b).
7. Placing the System into Operation
A. Slowly turn on the cold water supply. Ensure that the feed
adapter valve is also open.
B. Open faucet and flush filter for 20 minutes. Discard water.
C. Check for leaks at all fittings before leaving installation. If leaks
appear, see Troubleshooting.
NOTE: A drinking water cartridge may contain carbon fines (very
fine black powder). If carbon fines appear in the water, discard
water. More flushing is required if carbon fines are present.
NOTE: Initially, filtered water may appear cloudy. If cloudiness in
a glass of water disappears from the bottom; fine air bubbles are
present. This air within the water will disappear within a few weeks
after installation.
INSTALLATION IS NOW COMPLETE.
6 • FRESHPOINT F1000-DFB, F1000-B1B Filtration Systems Instruction Manual
5
6b
7
Closed to system
Open to system
Inlet
(white tubing)
6a
Outlet (blue tubing)