Technical data
SolBrid
Operating conditions
Area of application
Climate category i.a.w. IEC 60721-3-4
Altitude
External pollution degree
Ambient temperature
Storage temperature
Relative humidity
Noise emission (typical)
Equipment and design
Degree of protection
AC overvoltage category
PV / Bat overvoltage category
Combination of DC connection PV + battery
AC connection
Dimensions (X x Y x Z)
Weight
Communication interfaces
Integrated DC disconnector
Cooling principle
Test certificate
32
Installation and commissioning instructions
10-3-2
Indoors, outdoors
4K4H
Max. 2000 m above sea level
PD 3
-25 °C ... +60 °C
-30 °C ... +70 °C
0 % ... 100 %, condensing
31 dBA
IP65
III
II
2 + 1 pair
Wieland 5-pin
700 mm x 500 mm x 181 mm
28 kg
LAN connection (RJ45), WiFi
RS485 3 (COM)
RS485 2 (RJ45) battery interface
RS485 1 (RJ45) GridSwitch (mains isolator meter) and
approved energy meter
Yes, conform to DIN VDE 0100-712
Outside: convection cooling, inside: temperature-control-
ler ventilator, variable-speed, internal dust protection
Refer to certificates download at the product page of
the website
10-3-4
4 + 1 pair
Z02 | 2404 | 780.767